противоскользящее тиснение
Check the hydraulic oil before using the anti sliding plate embossing equipment. When the hydraulic oil height is 2/3 of the base height, when the refueling time is insufficient, fine filtration shall be carried out before fuel injection. It stands on the next filling hole 20 to add pure hydraulic oil. From the oil level benchmark, it is generally applicable to stations with a lower height of two-thirds.
Классификация:
Оборудование для тиснения защитной пластины
Детали
Check the hydraulic oil before using the anti sliding plate embossing equipment. When the hydraulic oil height is 2/3 of the base height, when the refueling time is insufficient, fine filtration shall be carried out before fuel injection. It stands on the next filling hole 20 to add pure hydraulic oil. From the oil level benchmark, it is generally applicable to stations with a lower height of two-thirds.
Check the lubrication between the guide pillar shafts and add oil in time to keep good lubrication.
Power, move the operating handle to the vertical position, close the oil return port, press the button to start the motor, oil enters the cylinder from the pump, and the piston drives it to rise. When the hot plate is closed, the pump continues to supply, and when the stop button is pressed, the oil pressure rises to the required value (14.5Mpa). When the machine is in the state of stopping packaging (i.e. timing vulcanization) and the curing time is reached, move the handle of the plunger to lower the mold.
Hot plate temperature control: turn off button SA1 to start the heating plate. When the temperature reaches the preset value, the heating will stop automatically. When the temperature is lower than the set value and the tablet is automatically heated, the temperature is always maintained at the set value.
Vulcanizer control operation: press the button to start the motor, etc. 2, the AC contactor will be energized, and the pump will run. When the hydraulic pressure reaches the set value, the AC contactor will be disconnected to automatically record the start curing time. When the pressure drops, the pump motor will start to automatically charge pressure, reaching S. ET curing time: Xiang Qi beeps to inform that the curing time is up. You can open the mode, press the buzzer stop button, move the manual valve, and the plate drops, which may be the next cycle.